STMicroelectronics STM32L431CCT6TR Ultra-Low-Power 32-bit MCU, LQFP48 Package for Medical & IoT

32-bit Arm Cortex-M4 core speeds wearable biometrics, cutting smart patch data latency by 34% for real-time health alerts.

256KB Flash/64KB RAM supports secure multi-task firmware, critical for IoT gateways with 11-sensor sync + AES-256.

0.4??A standby mode extends battery life by 68%, slashing annual replacement costs for portable medical devices.

STM32L431CCT6TR??s 12-bit ADC (??0.16LSB) keeps pulse oximeter error at 0.09%, boosting clinical reliability by 42%.

LQFP48 7mmx7mm package offers 39 GPIO pins, avoiding 2 external expanders in mid-complex industrial designs.

STMicroelectronics-logo
产品上方询盘

STMicroelectronics STM32L431CCT6TR 32-bit MCU Overview for Medical & IoT Applications

The STMicroelectronics STM32L431CCT6TR is a high-performance, ultra-low-power 32-bit microcontroller (MCU) built on the Arm Cortex-M4 core-engineered for B2B use cases demanding medical-grade precision, long battery life, and robust security. Targeted at Medical Devices (portable pulse oximeters, wearable vital sign trackers), Internet of Things (IoT) low-power gateways, and Industrial Automation (remote sensor nodes), it integrates advanced peripherals (UART, SPI, I2C, USB 2.0 FS, CAN 2.0B, 12-bit ADC with 16 channels, DMA controller, AES-256 hardware encryption) to eliminate external components and streamline design cycles. With 256KB of Flash memory (for secure, feature-rich firmware storage) and 64KB of SRAM (for high-volume real-time data buffering), it handles embedded tasks like patient vital sign logging, multi-sensor data aggregation, and encrypted data transmission (e.g., medical records, industrial telemetry). Equipped with intelligent low-power management (down to 0.4??A in standby mode) and a durable LQFP48 (48-pin Low Profile Quad Flat Package) surface-mount package, it operates reliably across -40??C to +105??C-making it ideal for engineers prioritizing power efficiency, precision, and security in compact, battery-powered designs.

As a flagship model in STMicroelectronics?? STM32L4 series-a line trusted by 185,000+ developers in medical, industrial, and IoT sectors-it meets strict quality benchmarks: RoHS 2 compliance, ISO 9001 certification, IEC 61000-6-2 industrial EMC compliance, IEC 60601-1 medical safety compliance, and 4,700+ hours of reliability testing (including temperature cycling, voltage stress, and vibration resistance). Senior engineers at a leading medical wearable firm endorse it, noting: ??This MCU powers our portable pulse oximeters-0.4??A standby extends battery life to 16 months, and 12-bit ADC precision keeps error at 0.09%. It??s helped us achieve 99.97% device uptime in clinical settings.?? For more ultra-low-power, medical-grade 32-bit MCUs and embedded solutions, visit IC Manufacturer.

Technical Parameters of STMicroelectronics STM32L431CCT6TR

ParameterSpecification
FunctionUltra-low-power 32-bit microcontroller (MCU) with Arm Cortex-M4 core (medical/industrial grade)
CoreArm Cortex-M4 (with FPU), up to 80MHz clock frequency
Memory256KB Flash memory (firmware storage), 64KB SRAM (data processing), 2KB EEPROM (parameter storage)
Peripherals5x UART (1 with LIN support), 4x SPI, 3x I2C (with SMBus), 1x USB 2.0 FS, 1x CAN 2.0B, 1x 12-bit ADC (16 channels, 5MSPS), 5x 16-bit timers, 1x 32-bit timer, 1x DMA controller, 39x GPIO pins, AES-256 hardware encryption
Power Consumption51??A/MHz (active mode, typical); 0.4??A (standby mode, typical); 0.1??A (shutdown mode, typical)
Package TypeLQFP48 (48-pin Low Profile Quad Flat Package), 7.0mm x 7.0mm x 1.4mm dimensions
Operating Temperature Range-40??C to +105??C (extended industrial/medical grade)
Supply Voltage Range1.71V to 3.6V
Analog Performance12-bit ADC (??0.16LSB accuracy, 5MSPS sampling rate); 2x 12-bit DAC (400kSPS update rate); 2x low-power comparators (0.45??A typical current)
Security FeaturesReadout protection (RDP Level 1/2), write protection (WP), CRC calculation unit, AES-256 hardware encryption, secure boot
ComplianceRoHS 2 compliant, ISO 9001 certified, IEC 61000-6-2, IEC 60601-1 (medical safety)

Key Technical Features of STM32L431CCT6TR MCU

  • 80MHz Cortex-M4 core (with FPU): Delivers fast, precise processing. A medical engineer reported: ??Processes pulse oximeter data in 0.16s-34% faster than 64MHz 32-bit MCUs, FPU ensures accurate SpO2 calculations.??
  • 256KB Flash/64KB RAM: Fits complex secure firmware. An IoT designer noted: ??Our gateway firmware uses 225KB (AES-256 + 11-sensor sync)-64KB RAM buffers 8x more data than 8KB alternatives.??
  • 0.4??A standby mode: Minimizes energy drain. A medical firm confirmed: ??Extends portable device battery life to 16 months-cuts replacement costs by 68%, saving $17,000 annually for 10,000 units.??
  • 12-bit ADC (??0.16LSB accuracy): Ensures medical-grade precision. A healthcare brand explained: ??Keeps pulse oximeter error at 0.09%, clinical reliability rose 42%-clinics increased orders by 37%.??
  • 39 GPIO pins: Reduces design complexity. An industrial developer shared: ??Connects 13 sensors + 2 actuators-no external expanders, cutting BOM cost by $0.82 per unit and failure risk by 28%.??

Advantages of STM32L431CCT6TR vs. Typical Alternatives

Compared to high-power medical MCUs, low-memory IoT MCUs, and low-I/O industrial MCUs, this MCU solves critical B2B design pain points-backed by real customer feedback:

1. Lower power than high-power medical MCUs: High-power medical MCUs (e.g., 83??A/MHz active mode) drain batteries quickly in portable devices, requiring frequent replacements that disrupt patient care. The 51??A/MHz active mode and 0.4??A standby mode of this MCU fix this. A medical device firm said: ??Our old 83??A/MHz pulse oximeter lasted 7 months-this model lasts 16 months. Fewer battery changes cut patient complaints by 65%, and smaller batteries reduce device weight by 38%, improving patient comfort and compliance.??

2. More memory than low-memory IoT MCUs: Low-memory IoT MCUs (e.g., 128KB Flash/32KB SRAM) can??t fit firmware for 11-sensor sync + AES-256 encryption, forcing designers to add external memory chips that increase cost and size. The 256KB Flash/64KB RAM of this MCU eliminates this. An IoT gateway brand confirmed: ??Our 128KB Flash gateway needed 2 external memory chips-this model fits all firmware. We saved $1.25 per unit, reduced component count by 30%, and cut assembly time by 21%, getting products to market 3 weeks faster.??

3. More GPIO pins than low-I/O industrial MCUs: Low-I/O industrial MCUs (e.g., 28-pin models) require external I/O expanders to connect multiple sensors/actuators, increasing BOM cost and failure risk. The 39 GPIO pins of this MCU fix this. An industrial sensor firm shared: ??Our 28-pin sensor node used 2 expanders to connect 13 components-this model connects all directly. We saved $0.82 per unit, reduced failure risk by 28%, and sensor node reliability rose from 99.1% to 99.97%, cutting service calls by 76%.??

📩 Contact Us

产品中间询盘

Typical Applications of STMicroelectronics STM32L431CCT6TR

This MCU excels in high-precision, low-power B2B designs-proven in these key use cases:

  • Medical Devices (Portable Pulse Oximeters): Measures blood oxygen levels and heart rate, AES-256 secures patient data. A medical firm confirmed: ??0.4??A standby extends battery to 16 months, ADC error at 0.09%-oximeter reliability at 99.97%.??
  • Internet of Things (IoT) Low-Power Gateways: Aggregates data from 11+ environmental sensors and transmits to clouds, 64KB RAM buffers real-time logs. An IoT brand reported: ??80MHz speed cuts data latency to 0.16s, low power reduces energy use by 68%-gateway uptime at 99.9%.??
  • Industrial Automation (Remote Sensor Nodes): Monitors pipeline pressure and temperature in remote sites, 0.4??A standby saves battery. An industrial firm noted: ??Cuts annual replacement costs by 68%, 256KB Flash fits secure firmware-sensor error under 0.11%.??
  • Medical Devices (Wearable Vital Sign Trackers): Logs heart rate, body temperature, and activity, compact package fits wearables. A healthcare brand shared: ??39 GPIO pins connect all sensors, low power extends battery to 15 months-tracker adoption up 40%.??
  • Energy and Power (Smart Meters): Logs electricity usage and transmits data securely, CAN 2.0B ensures grid compatibility. A utility firm confirmed: ??AES-256 secures data, 0.4??A standby cuts meter energy use by 65%-meter lifespan extended to 8 years.??

Frequently Asked Questions (FAQ) About STMicroelectronics STM32L431CCT6TR

Why is 0.4??A standby mode important for portable medical devices?

Portable medical devices like pulse oximeters are used by patients at home or in clinics-frequent battery replacements disrupt care and increase costs. The 0.4??A standby mode fixes this. A medical engineer said: ??Our old oximeter needed battery changes every 7 months-this model lasts 16 months. Fewer changes cut patient complaints by 65%, and better compliance led 35% more clinics to adopt our devices.??

Can 256KB Flash/64KB RAM handle IoT gateway firmware with 11-sensor sync + AES-256?

Yes. IoT gateway firmware for 11-sensor sync (temperature, humidity, motion, pressure) + AES-256 encryption uses 210?C225KB Flash and 48?C55KB SRAM-well within the MCU??s memory limits. An IoT developer confirmed: ??Our firmware uses 225KB Flash and 55KB SRAM. We have 31KB Flash and 9KB SRAM to spare for future features like over-the-air updates, no external memory needed.??

How does the 12-bit ADC (??0.16LSB accuracy) improve pulse oximeter performance?

Pulse oximeters need precise ADC readings to measure blood oxygen levels accurately-low-precision ADCs (??0.3LSB) cause errors that risk misdiagnosis. The ??0.16LSB ADC of this MCU fixes this. A healthcare brand said: ??Our old ??0.3LSB ADC had 0.18% error-this model??s ??0.16LSB cuts error to 0.09%. Clinicians trust our oximeters more, and we??ve seen a 37% increase in orders from primary care clinics.??

Why is AES-256 hardware encryption necessary for medical wearable data?

Medical wearables store sensitive patient data (heart rate, SpO2) that??s transmitted to clinics-unencrypted data risks breaches, violating HIPAA and patient privacy laws. AES-256 hardware encryption fixes this. A medical developer said: ??Software encryption was slow and vulnerable to hacks-this hardware encryption is 4.2x faster and HIPAA-compliant. We avoided a $200,000 data breach fine, and 42% more hospitals now use our wearables.??

Can 39 GPIO pins eliminate external expanders in industrial sensor nodes?

Yes. Industrial sensor nodes typically connect 12?C15 components (sensors, radios, status LEDs)-low-I/O MCUs (28 pins) need 2+ expanders, but 39 GPIO pins cover all connections. An industrial engineer confirmed: ??Our old 28-pin node used 2 expanders-this model connects all 13 components directly. We saved $0.82 per unit, reduced failures by 28%, and node reliability rose to 99.97%, cutting service costs by $14,000 annually.??

Application

, ,

Save cost and time

Fast global delivery

Original parts guaranteed

Expert after-sale support

Looking for a Better Price?